Compatibility
| Fits these systems |
|
|---|
Not sure it fits? Call (714) 541-6600
Technical Details
| Model Number | 602804 |
| Manufacturer | Viqua |
| Lamp Type | Low pressure high output mercury vapor |
| Base Design | Black base |
| Lamp Life | 9,000 hours (1 year) |
| Compatible Systems | Viqua B, B4 series |
| Output Characteristic | High output UV intensity |
| Ballast Compatibility | System-specific (genuine Viqua only) |
Lamp Replacement Procedure
- Disconnect power to the UV system and shut off water supply before beginning lamp replacement
- Remove the quartz sleeve from the chamber, then carefully extract the old lamp by grasping the black base and pulling straight out from the ballast connection
- Insert the new Viqua 602804 lamp into the ballast connector until seated, reinstall the quartz sleeve, and restore power to initiate the system
- Reset the lamp timer or mark the installation date to track the 9,000-hour service interval
System Requirements
The Viqua 602804 replacement lamp is engineered exclusively for Viqua B and B4 series ultraviolet water disinfection systems. This lamp requires a compatible Viqua ballast designed for low-pressure high-output mercury vapor operation. Using non-genuine replacement lamps or mismatched ballast configurations will compromise UV output and system warranty. Verify your system model before ordering to ensure proper fit and electrical compatibility.