UV Dynamics

UV Dynamics (400275) Replacement Quartz Sleeve for UVD20.40C, UVD1200 & UVD1500

Product Code 400275

$111.75

Compatibility

Fits these systems
  • UV Dynamics UVD20.40C, UVD1200, UVD1500
Replaces part numbers
  • UV Dynamics 400275

Not sure it fits? Call (714) 541-6600

UV Dynamics Replacement Sleeve

UV Dynamics 400275 Quartz Sleeve

Replacement quartz sleeve for UV Dynamics 20 GPM ultraviolet systems
✓ High-purity quartz✓ Approx. 49.13" long✓ OEM fit

Part 400275 is the quartz sleeve for the UV Dynamics UVD20.40C, UVD1200 and UVD1500 systems. The sleeve keeps the UV lamp dry while letting UV-C light pass into the water. Scale, iron staining or etching on the sleeve cuts the UV dose, so replace it every 2 years, or sooner if it is cracked or won't come clean.

Specifications

Sleeve Details

Part Number 400275
Brand UV Dynamics
Material Quartz glass
Length Approx. 49.13" (1248 mm)
Replacement Interval Every 24 months, or when cracked or permanently fouled
Fits UV Dynamics UVD20.40C, UVD1200, UVD1500
Matching UV Lamp UV Dynamics 400271
Why It Matters

A Clear Sleeve Means Full UV Dose

Protects the Lamp

Seals the lamp away from the water so it runs at the right temperature and stays dry.

Passes UV-C

Quartz transmits 254 nm UV-C light. Ordinary glass does not.

Fouling Blocks Light

Hardness, iron and manganese coat the sleeve over time and shield microbes from the lamp.

Exact OEM Fit

Correct length and diameter for the UV Dynamics 20 GPM chamber and its O-ring seals.

Installation

Sleeve Change Steps

  1. Unplug the system, shut off the water and relieve pressure on the UV chamber.
  2. Remove the lamp connector and lamp, then loosen the sleeve retaining nut(s).
  3. Pull the old sleeve out carefully and inspect the O-rings. Replace any that are flattened or cracked.
  4. Wipe the new sleeve with a lint-free cloth and slide it in until it seats evenly.
  5. Tighten the retaining nut(s) by hand, slowly restore water and check for leaks before reinstalling the lamp.

Hard water or iron? Install softening or iron filtration ahead of the UV unit to keep the sleeve clean between services.