Trojan (650645) UVMax G 120V UV System 19 GPM; Combo 1¼" NPT, 1" MNPT

Trojan (650645) UVMax G 120V UV System 19 GPM; Combo 1¼
Your Price:$1,775.00
Ships within 24-72 hours
Part Number:650645

The TrojanUVMax™ measurement of performance has been improved due to the ability of the lamp to deliver a constant, reliable dose. Customers can now feel comfortable treating ice-cold waters and hot water recirculation lines, in a cool basement or a hot pump house.  

Using an amalgam based lamp the system offers more intensity in a more compact footprint. These lamps have a two year lamp life. A CoolTouch fan is included in every system in order to significantly reduce the water temperature in the reactor during times of low or no flow. The system controller is equipped with an interface.

Flow Rate
(85% UVT eol)
VIQUA Standard
(30mJ/cm²)
72.0 lpm
(19.0 gpm)
(4.3 m³/Hr)
NSF/EPA
(40mJ/cm²)
57.0 lpm
(15.1 gpm)
(3.4 m³/Hr)
Dimensions Length 54.0 cm
(21.3 ")
Diameter 10.0 cm
(3.9 ")
Controller 33 x 16.5 cm
(13" x 6.5")
Inlet/Outlet Port Size Combo 1¼" NPT, 1" MNPT
Electrical Volts 120-240V
50-60Hz
Max. current 1.2 Amp
Power Consumption 120 W
Lamp Power 100 W
Operating Parameters Maximum Operating Pressure 100 PSI
(689 kPa)
Minimum Operating Pressure 10 PSI 
(69 kPa)
Ambient Temperature 0-40 °C
(32-104 °F)
Maximum humidity 100 %
Maximum hardness 120 ppm
(7 grains per gallon)
Maximum iron 0.3 ppm
Minimum UVT 75 %
Reactor Chamber Material 316L S.S.
UV Lamp Life 2 years
Colour-coded plug and play connections Yes
CoolTouch fan Yes
Solenoid Valve Optional
Controls Audible alarm mute button Yes
New lamp button Yes
Lamp age indicator Yes
Lamp operation indicator Yes
Ballast operation indicator Yes
Solenoid operation indicator Yes
Fan operation indicator Yes
Sensor reading indicator Yes
Installation Vertical